Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Zhejiang Yuanneng Power Technology Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Cynthia Huang
  • 电话:86-577-62708009
  • 传真:86-577-62708003
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 11kv Expulsion Fuse C/W Holder
11kv Expulsion Fuse C/W Holder
单价 $15.00 / Pieces对比
询价 暂无
浏览 206
发货 Chinazhejiangwenzhou
库存 120000Pieces
过期 长期有效
更新 2020-04-05 08:22
 
详细信息
Product Name: 11kv Expulsion Fuse C/W Holder Model NO.: YNC1-12/100 Fusing Device: Fuse Element Fusing Speed: K Shape: Dropout Usage: High Voltage Type: Current Fuse Breaking Capacity: High Rated Voltage: 11kv-15kv Trademark: YN Transport Package: Carton&Pallet or Wooden Case Specification: 100A/200A Origin: China HS Code: 85351000 Product Description 11kv Expulsion Fuse C/W HolderDrop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device. To be connected with incoming feeder of distribution transformer or distribution lines, it mainly protect transformer or lines from short circuit and overload, and on/off loading, current. Drop-out fuse cutout is composed of insulate insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube. Outer phenolic compound paper tube or epoxy glass tube, load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure switching on-off loading current.At normally working via fuse link tightened the fuse tube is fixed to form up of close position. In case system occur faults, fault current result result in fuse melt immediately and take piece electric are, which let arc-extinguishing tube being heated and explode a lot of gas, This will produce high pressure and below of the are along with tube. After fuse link melt moving contact has no tightened strength again, mechanism is locked and fuse tube drop out, Cutout now is in open position. When it needs to switch off during cutout loading, operator shall via insulating operating bar pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.Main Technical Parametes TypeRated voltage (kv)Ratedcurrent(A)Breakingcurrent(A)Impulsevoltage(BIL)Powerfrequency withstand voltageLeakage distance(MM)Weight(KG)Dimension(CM)YNC1-12/10012-151008000110402506.540*36*11.5YNC1-12/20012-1520010000110402506.5